Standards & Compliance

ASTM, NACE/AMPP, API, NFPA. The standards the Enerpro Tank Panel System is built to and the conformance documentation supplied on request.

The Enerpro Tank Panel System is manufactured and installed in conformance with the following standards. Project specifications referencing any of these documents can be matched directly. Material certificates and traceability documentation are supplied on request.

StandardScope
ASTM B209Aluminum and aluminum-alloy sheet and plate — jacketing substrate. Alloys 1100, 3003, 3105-H14 stocked.
ASTM C612Mineral fibre block and board thermal insulation. Type IVB rigid mineral wool board specified for the Enerpro insulation core.
ASTM E136Behavior of materials in a vertical tube furnace at 750 °C. Mineral wool core classified non-combustible.
ASTM A653Steel sheet, zinc-coated (galvanized) by the hot-dip process. One steel substrate option.
ASTM A792Steel sheet, 55% aluminum-zinc alloy-coated (galvalume). One steel substrate option.
ASTM A463Steel sheet, aluminum-coated (aluminized). One steel substrate option.
NACE SP0198 / AMPPControl of corrosion under thermal insulation and fireproofing materials — the standard underlying the Enerpro sealed-envelope design intent.
API 510Pressure vessel inspection code. Insulation system design supports in-service inspection regimes.
API 653Tank inspection, repair, alteration, and reconstruction.
NFPA-22Water tanks for private fire protection. Insulation supports thermal protection requirements for fire-water storage.
ASHRAE 90.1Energy standard for buildings. Referenced for envelope energy performance where applicable.

Conformance documentation supplied on request